Temperature Transmitters for Thermocouples
Our thermocouple transmitters offer very high accuracy and linearity, accurate built-in cold junction compensation, reverse polarity and surge protection, thermocouple failure detection and failsafe output. They can be mounted in the head of the thermocouple housing or on a 35 mm DIN rail.
GTT202 is a field programmable two wire loop power 4-20 mA temperature transmitters for most of the thermocouples in use and millivolts.
Features
- OUTPUT CAN BE LINEAR TO TEMPERATURE OR VOLTAGE, FIELD PROGRAMMABLE
- TOTAL ERROR IS LESS THAN 0.1 % FS
- BUILT-IN COLD JUNCTION COMPENSATION. CAN BE ENABLED OR DISABLED, FIELD PROGRAMMABLE
- COLD JUNCTION COMPENSATION ERROR LESS THAN 0.25 oC
- FIELD PROGRAMMABLE THERMOCOUPLE TYPE
- DEGREES C OR DEGREES F, FIELD PROGRAMMABLE
- THERMOCOUPLE FAILURE DETECTION
- FIELD PROGRAMMABLE FAILSAFE OUTPUT
- THE OUTPUT IS FIELD PROGRAMMABLE - OFFSET/SPAN, NORMAL/INVERSE
- REVERSE POLARITY AND SURGE PROTECTION
- HEAD MOUNT OR DIN RAIL MOUNT
- 44.4 mm dia x 15 mm H (1.75''dia x 0.6''H), HEIGHT INCLUDES THE TERMINALS
- WEIGHT 20 g (0.7 oz)

GpH140-12 has one input for pH / REDOX / ORP and one for mV / thermocouples.
GpH140-22 has two inputs for mV / thermocouples.
Both have as a standard one Pt1000 RTD input, the built-in cold junction compensation and one 4-20 mA two wire loop power input.
Thermocouples
- -10 to +100 mV
- Type B, NIST Monograph 175, IEC 584
- Type C, W5Re/W26Re, type W5, ASTM E 988-96
- Type E, NIST Monograph 175, IEC 584
- Type J, NIST Monograph 175, IEC 584
- Type K, NIST Monograph 175, IEC 584
- Type L, DIN 43710
- Type N, NIST Monograph 175, IEC 584
- Type R, NIST Monograph 175, IEC 584
- Type S, NIST Monograph 175, IEC 584
- Type T, NIST Monograph 175, IEC 584
- Type U, DIN 43710
|
|
|
|

|
|